DATA
SHEET
NITROGEN DIOXIDE SENSOR MODEL GVU-NO
2
DIESEL EXHAUST GAS DETECTOR
TYPICAL INSTALLATIONS:
• Parking Garages Vehicle Maintenance & Storage
• Bus Garages Highway Departments
• Fire Stations Utilities
• Warehouses Public Works
• Car Dealers Tunnels
FEATURES:
Power on indication
High NO
2
Indication
Fault Indicator
Low voltage class two (2) wiring
Convenient diagnostics
Simple maintenance
Operating range meets OSHA standard
GENERAL DESCRIPTION:
The model GVU-NO
2
nitrogen dioxide sensor is designed to interface
with Toxalert International GVU series control units. The Model GVU-
NO
2
utilizes an electrochemical sensing element and is designed for
ambient monitoring applications. It is intended for use in fixed
monitoring installations, and therefore continuous operation. The
GVU-NO
2
has an effective range of 0-10 ppm. The sensor module
requires a four-wire connection from a controller that provides a
nominal 24VDC power source, common and return signal input. The
GVU-NO
2
has indicators for power on, fault status and high NO
2
.
The Toxalert Nitrogen Dioxide (NO
2
) Transmitter combines safety and
energy savings. A common producer of NO
2
is diesel engine exhaust.
Diesel exhaust is a know cancer causing agent as reported in the U.S.
Department of Health and Human Services’ Current Intelligence
bulletin 50 dated August 1988. An electrochemical cell is required to
measure such small amounts of NO
2
. The device’s sensor is capable of
measuring NO
2
in increments of 0.1 ppm.
TOXALERT INTERNATIONAL, INC., P.O. BOX 159, MOUND, MINNESOTA 55364 (952) 472-4541 FAX (952) 472-4960
Visit our website at www. toxalert. com
TM
TOXALERT
Model GVU-NO
2
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - TOXALERT

DATASHEETNITROGEN DIOXIDE SENSOR MODEL GVU-NO2DIESEL EXHAUST GAS DETECTORTYPICAL INSTALLATIONS:• Parking Garages • Vehicle Maintenance & Storage•

Page 2 - INSTALLATION INSTRUCTIONS

•Type: Electro-chemical cell diffusion barrier type•Range: 0 to 10 ppm nitrogen dioxide in air•Response Time: 30 seconds to 90% indication•Typical lif

Page 3

INSTALLATION INSTRUCTIONSNOTE: Refer to Figure 2 and Tables 1 and 2.Use shielded cable to interconnect sensor andcontrol unit if metal conduit is not

Page 4 - GVU SERIES PRODUCTS:

GVU-NO2 5/07TOXALERT INTERNATIONAL, INC., P.O. BOX 159, MOUND, MINNESOTA 55364 (952) 472-4541 FAX (952) 472-4960Visit our website at www. toxalert. c