GVU-NO
2
5/07
TOXALERT INTERNATIONAL, INC., P.O. BOX 159, MOUND, MINNESOTA 55364 (952) 472-4541 FAX (952) 472-4960
Visit our website at www. toxalert. com
TABLE 2 WIRING CONNECTIONS
GVU-NO
2
CONTROL UNITS
SENSOR GVU-1 GVU-3
J2-1 TB11-24 VDC (+) TB3-H (+24VDC
J2-3 TB11-24 VDC (–) TB3-N (–24VDC)
J3-1 TB2-1 TB1-A1, B1, C1
J3-3 TB2-7 TB1-A7, B7, C7
** TB2-5 TB1-A5, B5, C5
** Shield of cable (if used) should be connected at control unit only. Make sure
sensor end is taped and isolated from terminals or metal
GVU SERIES PRODUCTS:
CONTROLLERS -
GVU-1 Control unit for use with one sensor
GVU-3 Control unit for use with one to three remote sensors
GVU-6 Control unit for use with one to six remote sensors
GVU-12 Control unit for use with one to twelve remote sensors
GVU-18 Control unit for use with one to eighteen remote sensors
REMOTE SENSORS -
GVU-CO Remote carbon monoxide sensor
GVU-CO
2
Remote carbon dioxide sensor
GVU-NO
2
Remote nitrogen dioxide sensor
GVU-VOC Remote smoke/air quality sensor